Magnetic Resonance in Medicine
Издатель: Wiley · ISSN 07403194 · 69 статей
-
Fast Voxelwise SNR Estimation for Iterative MRI Reconstructions
Purpose To develop a fast, general‐purpose framework for voxelwise noise characterization in iterative MRI reconstructions, recovering the image‐domain noise variance, the primary quantity from which SNR, ‐factor, and related...
-
Rigid Motion Estimation Using Accelerated Coordinate Descent (REACT) for MR Imaging
ABSTRACT Purpose To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods The proposed method, REACT, assumes a piecewise‐constant motion trajectory and estimates the rigid...
-
Optimal RF Phase Modulation for Improved Magnetic Resonance Fingerprinting T2 Encoding and Efficiency
ABSTRACT Purpose To improve magnetic resonance fingerprinting (MRF) T 2 encoding by combining phase‐based T 2 encoding with optimal experiment design. Methods Six hundred–timepoint MRF sequences with jointly optimized flip angle (FA)...
-
B1+$$ {B}_1^{+} $$ Optimization in the Heart at 7 T
ABSTRACT Purpose At 7 T, the short RF wavelength in tissue (∼11 cm) causes destructive interference within the chest, leading to inhomogeneity and posing a critical challenge for cardiac MRI and MRS. While subject‐specific...
-
Liver T1, T2, T2*, and PDFF Mapping at 0.55 T Using Rosette MRF With Optimized Sequence Design and Deep Image Reconstruction
ABSTRACT Purpose Quantitative imaging on mid‐field (0.55 T) MRI systems can suffer from poor precision due to low SNR. This work presents an MRF pulse sequence optimized with Cramer‐Rao lower bound (CRLB) and combined with a multi‐echo...
-
Combining Cartesian and Non‐Cartesian Acceleration Techniques With SPARKLING for 1 mm Isotropic Whole‐Brain MPRAGE in a Minute
ABSTRACT Purpose ‐weighted MPRAGE remains a cornerstone of clinical anatomical imaging, yet its long acquisition times constrain routine use. Established acceleration techniques, namely Parallel Imaging ( PI ) and Compressed Sensing (...
-
Improving Submillimeter BOLD fMRI Sensitivity With Localized Receive‐Coil Design at 7 T
ABSTRACT Purpose To evaluate whether a dense, small‐element receive array optimized for visual cortex imaging improves temporal SNR and BOLD sensitivity relative to a whole‐head coil at 7 T, and whether this depends on spatial...
-
Receive‐Only Coupled Wireless Radiofrequency Probe for Endocavity MR Imaging Using a pTx System
ABSTRACT Purpose To enhance the SNR in MRI within a localized region of interest using a novel interventional wireless RF resonator probe combined with a dual‐drive pTx system. Methods A dual‐drive body birdcage coil was operated in a...
-
Adaptive Mask‐Guided k‐Space Diffusion for Accelerated MRI Reconstruction
ABSTRACT Purpose Masked modeling has emerged as a powerful deep learning paradigm that reconstructs missing data by predicting masked regions, achieving strong performance across multiple domains. As a critical task in medical imaging,...
-
Short T1 Fraction as a Marker of Myelin Content: Evidence From Postmortem MRI and Histology
ABSTRACT Purpose To investigate the short‐T1 fraction as a potential biomarker of white matter myelin integrity, using myelin histology as ground truth. Methods Multi‐inversion‐time MRI data were acquired from four postmortem brain...
-
Quantitative Proton Density Mapping With Data‐Driven Reception Profile Correction Derived From Macromolecular Proton Fraction
ABSTRACT Purpose Proton density ( PD ) and macromolecular proton fraction ( MPF ) are fundamental MR parameters characterizing water and macromolecular content in tissues. Both parameters can be mapped using a time‐efficient MRI...
-
Stim‐CODE: PNS and CNS Constraint Optimized Diffusion‐Encoding for Neuroimaging on 200 mT/m Whole‐Body Gradients
ABSTRACT Purpose Ultra‐high‐performance whole‐body MRI gradients ( 200mT/m, 200 T/m/s) can reduce echo times (TE) in diffusion‐weighted imaging (DWI), improving SNR. However, full hardware utilization is limited by cardiac (CNS) and...
-
Time‐Resolved 3D Imaging and Strain Analysis of the Skeletal Muscle
ABSTRACT Purpose To develop and validate a method for time‐resolved 3D imaging and strain analysis that enables quantification of dynamic in vivo muscle deformations from aperiodic continuous motion. Theory and Methods Controlled...
-
Quantitative Susceptibility Mapping and R2* of Ischemia–Reperfusion Injury Relates to Reactive Oxygen Species Activity
ABSTRACT Purpose Iron deposition following ischemia–reperfusion injury (IRI) plays a catalytic role in reactive oxygen species (ROS) production, contributing to myocardial injury and subsequent heart failure. There is a need for...
- Effects of Lipid‐Induced Magnetic Microstructure on Fat Fraction Quantification in Muscular Dystrophies
- A Fast B1+$$ {B}_1^{+} $$‐Driven RF Co‐Simulation Optimization Method for RF Coil Arrays
- Optimized Gradient Waveforms for Tensor‐Valued Diffusion MRI Under Time‐Dependent Diffusion Using Double‐Isotropic Matched Encoding (DIME)
- Simplified Anisotropic IVIM Using Spherical Means and an Application in the Placenta
- Enhanced Blood Suppression in Magnetic Resonance Vessel Wall Imaging Using Toggled DANTE (tDANTE)
- A Modular Hybrid Framework for CEST MRI Development and Clinical Translation Using pTx‐Pulseq Preparation With Open‐ and Closed‐Source Readouts and ONNX Mapping
- Predicting Mesoscopic Larmor Frequency Shifts in Ex Vivo Porcine Optic Nerve
- An Inline‐Integrable Image Restoration Model With ROI Fine‐Tuning and Slice‐to‐Volume Reconstruction for Accelerated Whole‐Brain Vessel Wall Imaging
- Spatially Aware Acquisition‐Independent Deep Learning for IVIM MRI Parameter Estimation in Patients With Esophageal Cancer
- Optimizing Ex Vivo MRI and Controlling the Roll of the Specimen Using Container‐ and Brain‐Specific 3D‐Printed Holders
- Towards Faster Fetal 3D CINE Cardiac MRI Reconstruction Using Region‐Optimized Virtual Coils (ROVir)
- Whole‐Brain Diffusion MRI at 7T With Universal Multiband GRAPE pTx Pulses
- OpenMRF: A Modular, Vendor‐Neutral Open‐Source Framework for Magnetic Resonance Fingerprinting Using Pulseq
- Deep‐DSP2: Cross‐Domain Deep Learning Direct MR Signal Prediction for RF Shielding‐Free MRI
- Optimizing Oscillating Diffusion Gradients to Reduce Mechanical Vibration and Acoustic Noise on Ultra‐High Gradient Scanners
- Optimizing IMPULSED Acquisition Protocols for Clinical 3T Scanners Through Bayesian Experimental Design